skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Anderson, Gordon A"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Ion mobility spectrometry (IMS) can delineate gas-phase ions and probe their geometries. Coupling with electrospray ionization and MS has brought IMS to structural biology, revealing the macromolecular folding and subunit connectivity. However, the orientational averaging of ion–molecule collision cross sections (Ω) in the linear and field asymmetric waveform IMS (FAIMS) diminishes the resolution and structural specificity. In the novel low-field differential (LOD) IMS, a field too weak for ion heating (and thus FAIMS) aligns strong macrodipoles, capturing their magnitudes and directional Ω across the dipole (Ω⊥). However, the bisinusoidal waveforms (from FAIMS) have compromised the resolution, measurement accuracy, and correlation to the ion properties. Large ions amenable to LODIMS have low mobility and diffuse slowly, allowing the waveform frequencies down to ∼10 kHz. The low field and frequency permit generating the ideal rectangular waveforms with a flexible frequency and duty cycle by direct switching (impractical for FAIMS) in a miniature low-power format. This new IMS stage is evaluated for the exemplary large protein albumin (66 kDa) previously studied using the bisinusoidal waveform. The flat voltages and greater form factor initiate the differential IMS effect at lower fields, expand the separation space, and enable the quantification of Ω⊥ values by varying the duty cycle. 
    more » « less
    Free, publicly-accessible full text available April 29, 2026
  2. Recent improvements to the comparison-based method of digital waveform generation increased the reproducibility of the waveforms so that the higher-order Mathieu stability zones can be accessed reliably. Digitally driven quadrupole mass filters access these zones using a fixed AC voltage and rectangular waveforms that are defined by a duty cycle. In this context, the duty cycle is the fraction of the waveform period where the waveform remains in the high state. Because digitally driven quadrupoles navigate stability using a duty cycle, there is no need to apply a resolving DC offset between electrode pairs. Accessing the higher stability zones using a conventional resonantly-tuned RF requires the use of thousands of AC and DC voltages making the mode of operation less accessible with these devices. Stability zones higher than (1,1) and (2,1) have theoretical resolving powers that are on the order 1,140 and 3,447 at FWHM which drives efforts to practically access these operational conditions. Accessing these zones digitally requires the use of extremely precise waveforms. In a previous effort, waveform generation produced waveforms to reliably access the (1,1) and (2,1) zones without impacting performance. However, recent work found more improvement was needed to reliably access neighboring higher stability zones. Derived from that work, it was determined that a waveform resolution of ~10 ppm or less was needed to reliably access the (3,1) and (3,2) zones. The present work utilized digital waveforms that achieve this level of precision to experimentally access and characterize attributes of the (3,1) and (3,2) zones. This work dives into the investigation of different beam energies to overcome the destabilizing fringing fields, improve transmission, and their overall effect on the experimental resolving power and signal-to-noise. In addition, the AC voltage of the driving RF was varied to understand the effects on the initial ion beam energy that is needed to achieve balanced separation and how the overall signal-to-noise is affected. Lastly, an assessment was made on the effects of the temporal parameters of a digital mass scan on peak sensitivity, peak fidelity, and overall duration for a scan. 
    more » « less
  3. Excluding the ion source, an ion mobility spectrometer is fundamentally comprised of drift chamber, ion gate, pulsing electronics, and a mechanism for amplifying and recording ion signals. Historically, the solutions to each of these challenges have been custom and rarely replicated exactly. For the IMS research community few detailed resources exist that explicitly detail the construction and operation of ion mobility systems. In an effort to address this knowledge gap we outline a solution to one of the key aspects of a drift tube ion mobility system, the ion gate pulser. Bradbury-Nielsen or Tyndall ion gates are found in nearly every research-grade and commercial IMS system. While conceptually simple, these gate structures often require custom, high-voltage, floating electronics. In this report we detail the operation and performance characteristics of a wifi-enabled, MOSFET-based pulser design that uses a lithium-polymer battery and does not require high voltage isolation transformers. Currently, each output of this circuit follows a TTL signal with ~20 ns rise and fall times, pulses up to +/− 200 V, and is entirely isolated using fiber optics. Detailed schematics and source code are provided to enable continued use of robust pulsing electronics that ease experimental efforts for future comparison. 
    more » « less